Showing posts with label 330PN. Show all posts
Showing posts with label 330PN. Show all posts

Wednesday, July 29, 2015

Outdoor Installation of Bosch 330PN, 520PN & 520HN

In past years, Bosch had always had naturally drafting gas tankless water heaters that were specifically designed for the outdoors.  The 117,000 BTU Bosch 125BO and 425HNO outdoor units were designed for outdoor use; however, they were discontinued about three years ago.  The Bosch 125BO and the 425HNO did not require any power to operate and were naturally drafting. They also did not require any venting. (These heaters did come with a power cord, but the power cord was only to provide for freeze protection and was not required for the regular operation of the water heater.)

The only outdoor Bosch tankless water heaters that are currently available are direct vent units and they require power to operate and have a special outdoor vent cap (BTOK) to protect them from the elements.  These specific outdoor units also have built-in freeze protection that is good for ambient freezes for short periods of time.

Bosch does still offer three different naturally drafting gas tankless water heaters that do not require any power to operate and are intended for indoor use but can be installed outside under special situations. The Bosch 330PN, Bosch 520PN and the Bosch 520HN are all naturally drafting units that require no power to operate.  These units come in either Natural Gas (NG) or Liquid Propane (LP). 

These units can be mounted outside if they are well protected from the elements and are able to get plenty of combustion air when in operation (See Image below of Bosch 330PN LP installed outdoors on a tree).  The 75,000 BTU Bosch Therm 330PN and the 117,000 BTU Bosch Therm 520PN and 520HN tankless water heaters will not be covered under any manufacturer's warranty if the unit freezes or if the heater gets damaged by rain.  Bosch Thermotechnology may void any warranty for the heater at their discretion as the Bosch 330PN, 520PN and the 520HN are intended for indoor applications.



This photo shows the Bosch 330PN-LP installed in a protected case with a sloped roof. The case is open on the bottom to allow for the easy flow of make-up air.


This photo shows the 330PN-LP from the front view with a hinge on the custom-built case that allows for easy access to the tankless water heater's controls.

Tuesday, June 23, 2015

Venting a Bosch Therm 330PN into an Existing Chimney


The Bosch Therm 330PN is a naturally drafting gas tankless water heater and must be vented to the outside using a minimum of a 4" diameter galvanized type B gas vent.  Under no circumstances should the vent pipe be reduced in size.  There must be a minimum of a 12" rise off the top of the heater before any 45's or 90 degree elbows.  If there is to be a horizontal section before going into the chimney then try and keep it as short as possible.  The maximum horizontal run allowed is half of the total vertical vent height.  45's, 90 degree elbows and any horizontal length is not to be considered in the total gas vent height.

The Chimney the Bosch 330 PN tankless water heater is venting into must be the only thing going into the chimney.  The galvanized type B gas vent must run all the way up the chimney to an approved rain cap.  The minimum vertical vent height is 6 ft and any horizontal vent connectors or elbows are not to be considered in the total gas vent height.  All gas vent sections of pipe must be screwed together with sheet metal screws and properly supported.  The Bosch 330 PN may be vented into the chimney alone as long as it is lined with the correct tile or metal ling.  Consult local codes for proper lining of chimney.  You may not vent any other fuel burning appliances into any free space remaining in the chimney.  Please see the illustration below for venting into the chimney and always follow the instructions listed in the installation manual for the heater.

A = Minimum of 6 ft. rise
1.  Listed approved Rain Cap
2.  Horizontal vent connection rising 1/4" per ft.
3.  Establish a 12" rise before any elbows

Friday, February 28, 2014

Negative Air & Freeze Prevention for Bosch Tankless Water Heaters

Negative Air in the older Bosch naturally drafting units and the new Bosch tankless water heaters such as the Bosch Therm 520PN, 520HN and 330PN is something that needs to be considered when installing the tankless.

Negative air pressure in a structure occurs when air consumed by fuel burning appliances or exhaust systems in that structure exceeds the amount of air available.  Here is a list of items that consume air within a typical household:

• Stove exhaust fans
• Furnaces
• Water heaters
• Fireplaces/ Woodstoves are the worst as they consume a lot of combustion air
• Bath fans
• Dryers

All of these items must be taken into account when making provisions for a proper amount of fresh air from the outside.  If the building is new construction, air infiltration from the outside will be limited and provisions for extra air supply should be made. If the building is older construction, air may infiltrate into the house through unplanned sources such as window frames, door jams, sill plates or idle chimney flues. These sources still may not be providing the adequate amount of air and additional sources of fresh air should be considered.

Why Negative Air Is Bad

Cold air from the outside is drawn through the water heater’s flue pipe because other fuel burning appliances or exhaust systems in the structure require more air than the dwelling can supply. When the required amount of air for the fuel burning appliances or exhaust systems in the structure is not being supplied to them, they find the flue pipe on the water heater an acceptable means of supplying themselves. Thus, freezing cold air is pulled down the water heater’s flue, drawn over the copper heat exchanger, potentially freezing it and the water valve below. Because, when idle, the water heater holds only cold water, freezing can happen quickly possibly causing leaks or ruptures in the heat exchanger and/ or the water valve. The water heater does not pull air through its flue pipe – if you were to remove the heater, the air would continue to come down your flue pipe. You must have the air balanced in the structure to correct this problem. Consultation with a heating, ventilating and air conditioning (HVAC) specialist is recommended.]

There is also another alternative to combat negative air for the Bosch 1600P, 1600H, 520PN and 520HN naturally drafting heaters and that is to use the AQ4 powervent kit.  The AQ4 powervent kit is for venting the appliance out the sidewall of the building and comes with a termination hood with built in flapper to keep the cold air from coming in when the heater is not being used.  The AQ4 powervent kit requires power to operate the blower motor which blows the exhaust gases to the outside.  The AQ4 powervent kit is not approved for the older Bosch 1000P and the new Bosch Therm 330PN as the unit is not large enough to use the powervent motor.

All larger Bosch tankless water heaters that are direct vent units meaning they have a built in fan, are sealed combustion and have the ability to take the intake air from the outside should always use this method and take the combustion air from the outside in all cold climate areas.





Friday, January 31, 2014

Bosch Therm 330PN Replacing the Bosch Aquastar 38B


The Bosch Therm 330PN gas tankless water heater is a point-of-use water heater designed to provide instant hot water for two sinks. It can, in some locals be used to provide hot water for a single low flow shower.  

The Bosch 330PN is 75,000 BTU's and can deliver 2.6 GPM of hot water at a 45 degree F temperature rise. A regular shower head delivers about 2.0 - 2.5 GPM, so the Bosch 330PN is right on the edge for delivering water for a hot shower.

However, if you live in a warm climate, such as Texas, Southern California, Florida, Arizona, etc, then you probably do not need to raise the water temperature by 45 degrees, so the 330PN can work for a single shower.

Also, if you use a low-flow shower head that reduces your flow to say 1.5 GMP, then again you can have a hot shower with the Bosch 330PN.


We would not recommend the Bosch Therm 330PN for a regular flow shower head in New York -- it just will not be able to keep up and provide you with a hot shower due to the cold incoming water.  The Bosch Therm 330PN is not designed or approved for preheated inlet water..
The Bosch 330PN is a good replacement for the older Bosch Aquastar 38B. The 38B was 40,000 BTU's and only delivered about 1.3 GPM at the same 45 degree F temperature rise. So, the 330PN really is a much stronger water heater than the 38B ever was!

The Bosch Therm 330PN takes the same 4" venting as the 38B did and must be vented vertical up through the roof.  The 330PN CANNOT be powervented out the sidewall of the building.

The Bosch 330PN comes in both Natural Gas (NG) and Liquid Propane (LPG) models.


The Bosch 330PN is designed for heating potable water only and is not approved for space heating applications.





Tuesday, October 8, 2013

Bosch Therm 330PN is the Direct Replacement for Bosch 1000P


The new Bosch Therm 330PN is the direct replacement for the retail model Bosch 1000P.  Bosch is no longer making the retail model heaters and is only selling wholesale versions.  The Bosch 330PN comes in either Natural Gas (NG) or Liquid Propane (LP).  The only difference between the 330PN and the retail model 1000P is the color of the front cover.  The 330PN has a silver cover as the older 1000P had a white cover.  All of the other specifications are the same.

Specifications for Bosch Therm 330PN:
  • Piezo ignition system requires no electrical connection
  • 78%+ thermal efficiency
  • 75,000 BTU maximum input
  • 3.3 gallons per minute capacity at 35F degree rise
  • Endless hot water for 1 application at a time
  • Minimum activation flow rate of 0.5 gallons per minute
  • Minimum of 30 psi water pressure required
  • High to low temperature control
  • Vents with 4" galvanized B vent – natural draft
  • Built for durability and serviceability with 15-year warranty and 20+ year life expectancy
  • Available in NG and LP models
The Bosch 330PN is also a good replacement heater for the older Aquastar 38B as they both are similar in BTU size and both take a 4" vent pipe.

The Bosch 330 PN could also replace the older Paloma PH6.  The 330 PN is 75K BTU and the PH6 was 43,800 BTU but both heater are good for small applications for camps and cottages.  The 330PN takes a 4" vent pipe like the PH6 did.  Please be aware that the 330PN requires a minimum of 30 psi of water pressure.