Thursday, May 30, 2019

Marey GA16LPDP & Marey GA16NGDP In Stock!!

GlobalTowne is an Authorized Marey Distributor and we stock all the Marey gas and electric tankless water heaters.  GlobalTowne has warehouses all over the US so we can ship fast and usually within 1-2 days.  Marey is currently out of stock on the Marey GA16LPDP and Marey GA16NGDP gas tankless water heaters until June 27th of 2019.  GlobalTowne has plenty of stock on these heaters in all our warehouses across the US. 
Below are some of the features:

  • 117,000 BTU
  • comes set for either NG or LP
  • Battery ignition (no power required)
  • Vents using 5" diameter type B-Vent (Vertical)
  • 1/2" water/gas connections
  • delivers up to 3.5 gpm 
  • 2.6 gpm at a 55 degree temperature rise
  • High and low temperature settings
  • Summer & Winter settings
  • Silver color
Please call GlobalTowne at 888-726-9752 for furhter questions or to place an order.  We have plenty in stock!!



Tuesday, June 23, 2015

Venting a Bosch Therm 330PN into an Existing Chimney


The Bosch Therm 330PN is a naturally drafting gas tankless water heater and must be vented to the outside using a minimum of a 4" diameter galvanized type B gas vent.  Under no circumstances should the vent pipe be reduced in size.  There must be a minimum of a 12" rise off the top of the heater before any 45's or 90 degree elbows.  If there is to be a horizontal section before going into the chimney then try and keep it as short as possible.  The maximum horizontal run allowed is half of the total vertical vent height.  45's, 90 degree elbows and any horizontal length is not to be considered in the total gas vent height.

The Chimney the Bosch 330 PN tankless water heater is venting into must be the only thing going into the chimney.  The galvanized type B gas vent must run all the way up the chimney to an approved rain cap.  The minimum vertical vent height is 6 ft and any horizontal vent connectors or elbows are not to be considered in the total gas vent height.  All gas vent sections of pipe must be screwed together with sheet metal screws and properly supported.  The Bosch 330 PN may be vented into the chimney alone as long as it is lined with the correct tile or metal ling.  Consult local codes for proper lining of chimney.  You may not vent any other fuel burning appliances into any free space remaining in the chimney.  Please see the illustration below for venting into the chimney and always follow the instructions listed in the installation manual for the heater.

A = Minimum of 6 ft. rise
1.  Listed approved Rain Cap
2.  Horizontal vent connection rising 1/4" per ft.
3.  Establish a 12" rise before any elbows

Venting a Bosch Therm 520PN or 520HN into an Existing Chimney


The Bosch Therm 520PN and Bosch Therm 520HN are both naturally drafting gas tankless water heaters and must be vented to the outside using a minimum of a 5" diameter galvanized type B gas vent.  6" diameter type B gas vent is required for all installations over 2,000 ft above sea level.  Under no circumstances should the vent pipe be reduced in size.  There must be a minimum of a 12" rise off the top of the heater before any 45's or 90 degree elbows.  If there is to be a horizontal section before going into the chimney then try and keep it as short as possible.  The maximum horizontal run allowed is half of the total vertical vent height.  45's, 90 degree elbows and any horizontal length is not to be considered in the total gas vent height.

The Chimney the Bosch tankless water heater is venting into must be the only thing going into the chimney.  The galvanized type B gas vent must run all the way up the chimney to an approved rain cap.  The minimum vertical vent height is 6 ft and any horizontal vent connectors or elbows are not to be considered in the total gas vent height.  All gas vent sections of pipe must be screwed together with sheet metal screws and properly supported.  The masonry chimney may have to be tile or metal lined before the insertion of the gas vent pipe.  Consult local codes for proper lining of chimney.  You may not vent any other fuel burning appliances into any free space remaining in the chimney.  Please see the illustration below for venting into the chimney and always follow the instructions listed in the installation manual for the heater.
A = Minimum of 6 ft. rise
1.  Listed approved Rain Cap
2.  Horizontal vent connection rising 1/4" per ft.
3.  Establish a 12" rise before any elbows