GlobalTowne.com is pleased to report that as of April 9, 2010 we now have the Chilipepper CP600 in stock!
We thank all of our existing Chillipepper CP6000 customers for their patience as we waited for the manufacturer to fulfill our stock orders.
Steve
Tuesday, March 30, 2010
Saturday, February 20, 2010
Selkirk 5 Inch Type B Venting Double-Walled Galvanized
GlobalTowne stocks 5" Selkirk Metalbest Type B Double-walled Galvanized vent pipe for the Bosch AquaStar 1600H and 1600P tankless water heaters.
The Selkirk Metalbestos 5" Type B vent pipe will connect up directly with the 1600H and 1600P tankless hot water heaters and will also connect up directly with the Bosch H/P VVT vertical vent kit.
The Bosch H/P VVT vertical vent kit contains all of the venting parts needed to vent the Bosch 1600H and 1600P heaters through the roof except for the straight pipe.
Our customers have found that ONLY the Selkirk Metalbest vent pipe will mate up with the H/P VVT vent kit piping, so this is the 5" Type B venting that we stock.
Steve
Monday, February 8, 2010
Z-Vent Installation Tips and Hints
GlobalTowne is one of Z-Flex's largest distributors in the US. We carry all of the Z-Flex Z-Vent stainless steel vent pipe that is needed to exhaust tankless water heaters and boilers.
Here are some generic Z-Vent Installation Tips and Hints directly from the vendor:
Steve
Here are some generic Z-Vent Installation Tips and Hints directly from the vendor:
- A venting system that exits the structure through a sidewall or the like, shall terminate not less than 12 inches (254 mm) above the ground.
- The termination of a system shall be located above the snow line in geographical areas where snow accumulates. The termination area should be kept clear of snow and ice at all times.
- The vent shall not terminate less than 7 ft. (2.13 m) above a paved sidewalk or driveway.
- The termination shall be 6 ft. (1.8m) or more from the combustion air intake of any appliance.
- The system shall terminate more than 3 ft. (.91 m) from any other building opening, gas utility meter, service regulator or the like.
- Exterior mounted venting systems should be enclosed below the roof line with a chase to limit condensation and protect against mechanical failure.
Steve
Saturday, February 6, 2010
AE 115 and AE 125 Heaters and control
Many times we have been asked if the Bosch AE115 and Bosch AE125 can accept pre heated water. The answer is no.
The reason lies in how the unit controls the temperature. These large KW whole house tankless water heaters are designed to take cool water and heat the water to shower temperature as the water passes through the heater. The heater turns on as flow is detected and turns off when the water flow ceases.
There is a temperature sensor on the inlet water pipe (cold) and a sensor on the outlet pipe (hot). The switch that turns the heater on is a solid state style switch or SCR switch. This type of switch has no moving parts and is very reliable. However, SCR or solid state switches generate heat as they switch electrical current. To cool these switches, they have been located on the inlet (cold) water inlet. So the copper pipes act as a heat sink for the SCR switches. If hot water is passed through the pipes and the heater turns on the SCR switches could over heat and FAIL.
Call us for any applications involving the need to have pre-heated water through a tankless heater. We can provided gas and electric heaters for floor heating or other applications needing to circulate warm or hot water.
Visit Globaltowne.com
The reason lies in how the unit controls the temperature. These large KW whole house tankless water heaters are designed to take cool water and heat the water to shower temperature as the water passes through the heater. The heater turns on as flow is detected and turns off when the water flow ceases.
There is a temperature sensor on the inlet water pipe (cold) and a sensor on the outlet pipe (hot). The switch that turns the heater on is a solid state style switch or SCR switch. This type of switch has no moving parts and is very reliable. However, SCR or solid state switches generate heat as they switch electrical current. To cool these switches, they have been located on the inlet (cold) water inlet. So the copper pipes act as a heat sink for the SCR switches. If hot water is passed through the pipes and the heater turns on the SCR switches could over heat and FAIL.
Call us for any applications involving the need to have pre-heated water through a tankless heater. We can provided gas and electric heaters for floor heating or other applications needing to circulate warm or hot water.
Visit Globaltowne.com
Thursday, February 4, 2010
Pipe Cover Kit (AQPCES) for AquaStar 2700ES / 2400ES
The Pipe Cover Kit (AQPCES) for the Bosch AquaStar 2700ES / 2400ES tankless water heaters is a cosmetic case that is installed directly below the tankless water heater. It covers the water and gas pipes from view.
This pipe cover kit will also work with the Bosch ProTankless Models: GWH 715 ES, GWH C 800 ES, GWH C 920 ES, GWH C 920 ESC.
Please review the AQPCES Installation Manual for more details.
This pipe cover kit will also work with the Bosch ProTankless Models: GWH 715 ES, GWH C 800 ES, GWH C 920 ES, GWH C 920 ESC.
Please review the AQPCES Installation Manual for more details.
Tuesday, January 5, 2010
Bosch Tankless Water Heater Parts
GlobalTowne sells replacement parts for current and discontinued Bosch Tankless Water Heaters.
We do not list these parts on our web site, but we can get them for you.
We need you to provide us with the part number that you need and we will get you pricing and availability.
All Bosch tankless water heater replacement parts are non-refundable.
All Bosch replacement parts can be shipped via Next Day Air, 2nd Day Air or Ground service.
Just give us a call at 888.726.9752.
Steve
We do not list these parts on our web site, but we can get them for you.
We need you to provide us with the part number that you need and we will get you pricing and availability.
All Bosch tankless water heater replacement parts are non-refundable.
All Bosch replacement parts can be shipped via Next Day Air, 2nd Day Air or Ground service.
Just give us a call at 888.726.9752.
Steve
Tuesday, December 8, 2009
Bosch 2700ES Vs. Bosch Pro 715ES - A Comparison
The Bosch AquaStar 2700ES tankless hot water heater is similar in many respects to the Bosch Pro 715ES tankless hot water heater.
They are both 199,000 BTU tankless water heaters and they both sit in the same chassis or case - the new "World 2" case.
Both have modulating gas valves and have the same .65 GPM minimum activation rate.
There are a few key differences between the two heaters, though.
One key difference is that the Bosch 2700ES comes with built-in freeze protection. This freeze protection is meant to keep the heater from freezing in locatons that experience occasional overnight freezes. The Bosch Pro 715ES does not come with this freeze protection -- but it is an optional accessory that you can pay extra for.
Another difference between these two heaters is the water filter.
In the Bosch 2700ES tankless hot water heater the water filter comes with the heater and is very easily accessible without having to even remove the cover. As you can see from this image, (1) is the water filter.
Bosch recommends that you inspect and clean the water filter once per year as part of your annual maintenance of the heater.
With the Bosch Pro 715ES, the water filter is an optional accessory - albeit a highly recommended accessory!
The Bosch Pro 715ES is a wholesale product that is meant to be sold directly to an installer. It is designed to be professionally installed. As such, it comes with a 15 year warranty. The Bosch 2700ES is a retail product that is meant to be sold directly to home owners and it comes with a 12 year warranty.
Steve
They are both 199,000 BTU tankless water heaters and they both sit in the same chassis or case - the new "World 2" case.
Both have modulating gas valves and have the same .65 GPM minimum activation rate.
There are a few key differences between the two heaters, though.
One key difference is that the Bosch 2700ES comes with built-in freeze protection. This freeze protection is meant to keep the heater from freezing in locatons that experience occasional overnight freezes. The Bosch Pro 715ES does not come with this freeze protection -- but it is an optional accessory that you can pay extra for.
Another difference between these two heaters is the water filter.
In the Bosch 2700ES tankless hot water heater the water filter comes with the heater and is very easily accessible without having to even remove the cover. As you can see from this image, (1) is the water filter.
Bosch recommends that you inspect and clean the water filter once per year as part of your annual maintenance of the heater.
With the Bosch Pro 715ES, the water filter is an optional accessory - albeit a highly recommended accessory!
The Bosch Pro 715ES is a wholesale product that is meant to be sold directly to an installer. It is designed to be professionally installed. As such, it comes with a 15 year warranty. The Bosch 2700ES is a retail product that is meant to be sold directly to home owners and it comes with a 12 year warranty.
Steve
Monday, November 30, 2009
Cyber Monday Bosch Tankless Water Heater Sale
Today is Cyber Monday!
GlobalTowne.com is offering 10% off all Bosch tankless water heaters, vent kits, individual pieces of Z-Flex stainless steel venting, Flow-Aide Descaler Kits and Webstone isolation valve kits.
In fact, we are offering 10% off everything we sell!
This is our biggest sale of the year and it is TODAY ONLY - until midnight ET, November 30, 2009!
Just enter Promotional Code CYBERMONDAY at checkout to get your 10% off savings!
Please note that some items on our online store show our regular low price crossed out with the Cyber Monday 10% off sale price already displayed.
Steve
GlobalTowne.com is offering 10% off all Bosch tankless water heaters, vent kits, individual pieces of Z-Flex stainless steel venting, Flow-Aide Descaler Kits and Webstone isolation valve kits.
In fact, we are offering 10% off everything we sell!
This is our biggest sale of the year and it is TODAY ONLY - until midnight ET, November 30, 2009!
Just enter Promotional Code CYBERMONDAY at checkout to get your 10% off savings!
Please note that some items on our online store show our regular low price crossed out with the Cyber Monday 10% off sale price already displayed.
Steve
Saturday, November 21, 2009
Tankless Water Heater Incentives and Rebates
At GlobalTowne we want to help our customers save every penny they can on purchases of Bosch Tankless Water Heaters.
In this blog we have already discussed in detail the 2009-2010 Federal Tax Rebate for certain Bosch high-efficiency tankless water heaters.
You may also qualify for additional rebates that are available in the US through your Energy Star partners. Please see the list of Special Offers and Rebates available from Energy Star Partners.
In the United States you can also review the Database of State Incentives for Renewables and Efficiency (DSIRE). This database may help you identify additional incentives that are available at your state or local government levels.
In Canada your new Bosch Tankless Water Heater may also qualify you for a Canadian Tax Rebate.
Going tankless with Bosch will save you on your gas, propane or electric utility bills. With these additional incentives available now there has never been a better time to Go Tankless!
Steve
Friday, November 20, 2009
Reconditioned Bosch Tankless Water Heaters
GlobalTowne sells factory-reconditioned Bosch Tankless Water Heaters. Please call us at 888.726.9752 for pricing.
All Bosch reconditioned tankless water heaters are refurbished and certified by Bosch. They carry the full Bosch warranty. Since we can sell these certified, factory-reconditioned tankless heaters to you at lower costs, you can realize significant cost savings.
Factory-refurbished tankless water heaters may have small dents or dings. However, Bosch Technical Support will provide you with the same level of technical support and customer service as if you had purchased a brand new tankless water heater. There is no risk when purchasing these "like new" tankless water heaters!
Supplies are limited by the speed at which Bosch is able to recondition the water heaters, so not every model is available at any given time.
Just give us a call and we will let you know if we have the reconditioned Bosch tankless water heater in stock that you desire.
Steve
Wednesday, October 28, 2009
Z-Flex 3" Termination Options for Bosch 2700ES/2400ES Tankless Water Heaters
We stock the full line of Z-Flex Z-Vent 3" and 4" stainless steel vent pipe. There are a variety of termination options for both the 3" and 4" venting.
All of our termination pieces come with a built-in bird screen to ensure that birds and other critters cannot get into your venting system.
The AQ3ES Side Wall Vent Kit for the Bosch 2700ES and 2400ES tankless water heaters comes with the 3" Termination Box with a 10" sleeve (2SVSTB03). This special OEM part is exactly the same as the Z-Flex part 2SVSRTF03. The 2SVSTB03 and the 2SVSRTF03 can both also be used for intake air.
If you have vinyl siding then you do not want to use the 2SVSTB03 or 2SVSRTF03 Termination Box as the hot exhaust gases may melt your vinyl siding. The recommended part for vinyl siding is the 3" Termination Hood (2SVSHTX03). This part can also be used for intake air.
We also sell the 3" Termination Hood with Damper (2SVSHTD03), but this part is not approved for either the Bosch 2700ES or Bosch 2400ES tankless heaters. The concern is that if the damper gets frozen shut then the exhaust gases cannot escape. The 3" Termination Hood with Damper cannot ever be used for intake air!
We carry the 3" Termination Coupling (2SVSTPF03). This will exhaust the gases straight out from your house, so safety is a concern when using this part for exhaust. This part can be used for either exhaust or intake.
The 3" Termination Tee (2SVSTTF03) exhausts the gases out in two directions. This part can also be used for intake air.
The 3" Termination Elbow (2SVSTEX0390) will shoot the exhaust gases out in a single direction. This part can also be used for intake air.
The Z-Flex Z-Vent 4" stainless steel vent pipe part numbers are as follows:
All of our termination pieces come with a built-in bird screen to ensure that birds and other critters cannot get into your venting system.
The AQ3ES Side Wall Vent Kit for the Bosch 2700ES and 2400ES tankless water heaters comes with the 3" Termination Box with a 10" sleeve (2SVSTB03). This special OEM part is exactly the same as the Z-Flex part 2SVSRTF03. The 2SVSTB03 and the 2SVSRTF03 can both also be used for intake air.
If you have vinyl siding then you do not want to use the 2SVSTB03 or 2SVSRTF03 Termination Box as the hot exhaust gases may melt your vinyl siding. The recommended part for vinyl siding is the 3" Termination Hood (2SVSHTX03). This part can also be used for intake air.
We also sell the 3" Termination Hood with Damper (2SVSHTD03), but this part is not approved for either the Bosch 2700ES or Bosch 2400ES tankless heaters. The concern is that if the damper gets frozen shut then the exhaust gases cannot escape. The 3" Termination Hood with Damper cannot ever be used for intake air!
We carry the 3" Termination Coupling (2SVSTPF03). This will exhaust the gases straight out from your house, so safety is a concern when using this part for exhaust. This part can be used for either exhaust or intake.
The 3" Termination Tee (2SVSTTF03) exhausts the gases out in two directions. This part can also be used for intake air.
The 3" Termination Elbow (2SVSTEX0390) will shoot the exhaust gases out in a single direction. This part can also be used for intake air.
- 4" Termination Box 2SVSRTF04
- 4" Termination Hood 2SVSHTX04
- 4" Termination Hood with Damper 2SVSHTD04
- 4" Termination Coupling 2SVSTPF04
- 4" Termination Tee 2SVSTTF04
- 4" Termination Elbow 2SVSTEX0490
Monday, October 19, 2009
Noritz 0751 Series Residential Tankless Water Heater
Today we received a call from a customer who was looking for 4" stainless steel vent pipe for his Noritz 0751 Series Residential Tankless Water Heater.
He wanted to purchase Z-Flex vent pipe and wanted to know the correct venting adaptor for this heater. He also wanted to know how to connect the Z-Flex exhaust to his Noritz VT4-TL Sealed Combustion Long Vent Termination.
The correct Z-Flex adaptor for the Noritz 751M-DV tankless water heater is the 4" Noritz Adaptor (2SVWA04). This adaptor connects directly to the heater and allows you to exhaust with Z-Flex 4" stainless steel vent pipe.
He wanted to purchase Z-Flex vent pipe and wanted to know the correct venting adaptor for this heater. He also wanted to know how to connect the Z-Flex exhaust to his Noritz VT4-TL Sealed Combustion Long Vent Termination.The correct Z-Flex adaptor for the Noritz 751M-DV tankless water heater is the 4" Noritz Adaptor (2SVWA04). This adaptor connects directly to the heater and allows you to exhaust with Z-Flex 4" stainless steel vent pipe.
The Z-Flex Stainless Steel Vent Pipe connects directly to the Noritz VT4-TL Sealed Combustion Long Vent Termination.
Steve
Steve
Thursday, October 15, 2009
ESHCK Concentric Vent Kit for Bosch 2700ES / 2400ES
Bosch has recently approved the ESHCK Concentric Vent Kit for the Bosch AquaStar 2700ES, 2400ES and 715ES tankless water heaters.
The ESHCK side wall concentric vent kit is actually a shell piece of stainless steel venting that will work with vent pipe manufactured by Z-Flex, ProTech Industries or Heat-Fab. (Of course, we always recommend using Z-Flex stainless steel AL29-4C vent pipe.)
Part number ESHCK is a 5" diameter shell through which you can stick a 3" x 3' piece of stainless steel vent pipe. This piece of straight pipe is terminated by either a Termination Tee or a Termination Elbow. The ESHCK shell that fits around this straight pipe creates the air intake vent pipe.
The air intake from the Bosch 2700ES, 2400ES or 715ES tankless water heater can be run using PVC and connects directly to the ESHCK. The air intake port on the ESHCK can be rotated 360 degrees around the ESHCK to bring the combustion air in from any angle. Bosch recommends that you bring the air in from the top, particularly in areas that are prone to freezing.
The ESHCK is actually 20" long, but when you stick the 3" x 3' pipe and the termination piece through the ESHCK then the total length of the ESHCK Vent Kit is about 41" long. When you add the required 3" x 90 degree elbow the total length is about 47" long. The square flashing that rests against the outside wall is 8" square.
Bosch requires that the termination tee or termination elbow be a full 12" away from your exterior wall. This is meant to ensure that the exhaust air does not get recylcled back through the air intake. Don't go beyone the 12" either as this may increase your potential for condensation in the exposed pipe section.
We sell a complete kit called the ESHCK-FULL-KIT Concentric Vent Kit that includes the ESHCK shell, a 3" x 90 degree elbow, a 3" x 3' stick of pipe and a termination tee.
Please note that this concentric vent kit will protrude quite a bit through the inside wall making it very difficult for you to mount the tankless water heater on the same wall that you are venting out of. The easiest way to use this ESHCK concentric vent kit is to mount your tankless water heater on a wall that is perpendicular from the wall that you are venting out of.
With this configuration, you will need a 90 degree elbow coming off of your water heater. Then we recommend using a horizontal drain pipe to catch any condensate that gets generated. Then you may need additoinal straight pipe to connect up to the ESHCK concentric vent kit which protrudes from the wall.
If you do want to do and "up and out" venting through the same wall you mount the heater on with the ESHCK then you will need to install your 2700ES or 2400ES tankless water heater out away from the wall. This will help you avoid using an excessive number of 90 degree elbows.
One of the big advantages of using the ESHCK concentric vent kit is that you only have to have a single hole through your exterior wall. This may greatly reduce your installation costs if you have a difficult wall to drill through, such as a thick stone wall.
Another advantage of using the concentric vent kit is that for some installations it is impossible to meet the 3' distance requirement between the exhaust and the air intake.
Aesthetically it may also be more desireable to have a single vent through your outside wall.
Please see the Bosch 2700ES Installation Manual or the 2400ES Installation Manual for the full details of installing the ESHCK Concentric Vent Kit.
Steve
The ESHCK side wall concentric vent kit is actually a shell piece of stainless steel venting that will work with vent pipe manufactured by Z-Flex, ProTech Industries or Heat-Fab. (Of course, we always recommend using Z-Flex stainless steel AL29-4C vent pipe.)
Part number ESHCK is a 5" diameter shell through which you can stick a 3" x 3' piece of stainless steel vent pipe. This piece of straight pipe is terminated by either a Termination Tee or a Termination Elbow. The ESHCK shell that fits around this straight pipe creates the air intake vent pipe.
The air intake from the Bosch 2700ES, 2400ES or 715ES tankless water heater can be run using PVC and connects directly to the ESHCK. The air intake port on the ESHCK can be rotated 360 degrees around the ESHCK to bring the combustion air in from any angle. Bosch recommends that you bring the air in from the top, particularly in areas that are prone to freezing.
The ESHCK is actually 20" long, but when you stick the 3" x 3' pipe and the termination piece through the ESHCK then the total length of the ESHCK Vent Kit is about 41" long. When you add the required 3" x 90 degree elbow the total length is about 47" long. The square flashing that rests against the outside wall is 8" square.
Bosch requires that the termination tee or termination elbow be a full 12" away from your exterior wall. This is meant to ensure that the exhaust air does not get recylcled back through the air intake. Don't go beyone the 12" either as this may increase your potential for condensation in the exposed pipe section.
We sell a complete kit called the ESHCK-FULL-KIT Concentric Vent Kit that includes the ESHCK shell, a 3" x 90 degree elbow, a 3" x 3' stick of pipe and a termination tee.
Please note that this concentric vent kit will protrude quite a bit through the inside wall making it very difficult for you to mount the tankless water heater on the same wall that you are venting out of. The easiest way to use this ESHCK concentric vent kit is to mount your tankless water heater on a wall that is perpendicular from the wall that you are venting out of.
With this configuration, you will need a 90 degree elbow coming off of your water heater. Then we recommend using a horizontal drain pipe to catch any condensate that gets generated. Then you may need additoinal straight pipe to connect up to the ESHCK concentric vent kit which protrudes from the wall.
If you do want to do and "up and out" venting through the same wall you mount the heater on with the ESHCK then you will need to install your 2700ES or 2400ES tankless water heater out away from the wall. This will help you avoid using an excessive number of 90 degree elbows.
One of the big advantages of using the ESHCK concentric vent kit is that you only have to have a single hole through your exterior wall. This may greatly reduce your installation costs if you have a difficult wall to drill through, such as a thick stone wall.
Another advantage of using the concentric vent kit is that for some installations it is impossible to meet the 3' distance requirement between the exhaust and the air intake.
Aesthetically it may also be more desireable to have a single vent through your outside wall.
Please see the Bosch 2700ES Installation Manual or the 2400ES Installation Manual for the full details of installing the ESHCK Concentric Vent Kit.
Steve
Sunday, August 30, 2009
Propane and Propane Tankless Water Heaters
There has never been a better time for propane to fuel American homes. Homeowners are looking for smart approaches to enhancing home enjoyment and value while minimizing environmental impact. Whether providing an instant flame for gourmet cooking or offering an endless supply of hot water in the shower or backyard pool, propane is helping millions of American families enjoy richer, more comfortable lives with less impact on the planet. And the lower cost of operation means homeowners will be rewarded for a smart choice each month with lower energy bills. Getting more for less while helping the environment - that’s a message worth sharing.
- Propane tankless water heaters produce 61 percent fewer greenhouse gas emissions than electric tankless models.1
- Propane tankless water heaters save families an average of 10 to 20 percent of their daily water use.2
- Propane tankless water heaters reduce standby energy loss by up to 20 percent compared with tank water heaters.2
- Propane tankless water heaters cost approximately 60 percent less to operate than tank water heaters.2
- Propane tankless water heaters are Energy Star qualified for efficiency; electric tankless water heaters are not.
Note: Using any kind of Tankless Water Heater is better for the environment than using a tank water heater. And even though electric tank water heaters are not energy star rated, that are significantly more environmentally friendly and less costly to operate than even Energy Star rated electric TANK water heaters.
Tuesday, July 7, 2009
Bosch Tankless Approval Codes/National Listings
All Bosch Gas Tankless Water Heaters are Compliant with ASHRAE 90.1 and are CSA design certified.
Please visit: www.bosch-climate.us for all other codes and cerifications.
All Bosch Electric Tankless Water Heaters and Electric Mini-tanks are UL and cUL approved.
Please visit: www.bosch-climate.us for all other codes and cerifications.
Wednesday, July 1, 2009
Replacing Legacy Bosch Tankless Heaters
We have just started getting some calls from customers who are looking to replace some of the original Commercial Bosch Tankless Water Heaters that were introduced into the market 20 years ago.
If you are looking to replace any of the following Bosch On-Demand Water Heaters, please give us a call at 888.726.9752 so we can help you match your heater up with its current replacement model:
If you are looking to replace any of the following Bosch On-Demand Water Heaters, please give us a call at 888.726.9752 so we can help you match your heater up with its current replacement model:
- Bosch WR400-1K (117,000 BTU, Pilot Light)
- Bosch WR400-3K (B) (117,000 BTU, Electronic Ignition)
- Bosch WR400-5K (117,000 BTU, Pilot Light)
- Bosch WR400-7K (117,000 BTU, Hydro Ignition)
- Bosch WR430-3KV (125,000 BTU, Electronic Ignition)
- Bosch WR125-K (125,000 BTU, Pilot Light)
Steve
Monday, June 29, 2009
Keltech Electric Tankless Water Heaters
Keltech Electric Tankless Water Heaters
Electric tankless water heaters are an alternative water heating solution compared to the traditional boiler or tank. In a Keltech tankless water heater, water is quickly heated to temperature as it passes through the copper and brass constructed heater core. Tankless water heaters are also referred to as “on-demand,” “in-line” or “booster” water heaters.
The Keltech Tankless Advantage
Keltech’s commercial grade tankless water heaters and fluid heating solutions are built for commercial and industrial process heating applications. Keltech heaters are used in applications as varied as:
• Safety shower and emergency eyewash applications
• Large industrial process heating
• Sporadic water heating for laboratories
• Light industrial process heating
• Aircraft hot water delivery systems
• Residential systems
• De-ionized water heating solutions
• Corrosive fluid heating protection systems
• Non-flammable fluid heating applications
• Other on-demand water heating applications
• Bio-diesel vegetable oil heating at 230°F
• Removing residue and oils from machine parts
• Circuit board flux removal
• Legionella prevention
• ANSI compliant safety shower heaters and systems
• ANSI compliant emergency eyewash heaters
Tankless Water Heaters and Water Heating Solutions for Extreme Environments
Freeze ProtectionWater heating solutions can be freeze protected to perform when air temperatures get as cold as -30°F.
Explosion Proof
Keltech also manufactures Class 1 Div 2 explosion proof solutions for highly volatile or flammable areas where water or chemicals must be heated.
NEMA 4x Enclosures
Keltech also produces water heaters that can be sealed in NEMA 4x enclosures to protect the investment from corrosive conditions and hostile environments.
Specialty ApplicationsKeltech also engineers and manufactures custom built tankless water heating solutions that are capable of heating:
• De-ionized Water
• Reverse Osmosis Fluids
• Corrosive Fluids
• Non-Flammable Fluids
Electric tankless water heaters are an alternative water heating solution compared to the traditional boiler or tank. In a Keltech tankless water heater, water is quickly heated to temperature as it passes through the copper and brass constructed heater core. Tankless water heaters are also referred to as “on-demand,” “in-line” or “booster” water heaters.
The Keltech Tankless Advantage
- Precise Temperature Control Keltech water heating solutions can be programmed to meet a specific temperature range. If needed, Keltech can also heat water precisely to within +/- 1 degree for temperature sensitive applications. Keltech safety shower heaters and eyewash heaters quickly reach ANSI compliant tepid water temperatures.
- Energy EfficientWater is heated only when needed. Unlike a boiler, there is no need to heat water 24 hours a day, 7 days a week, 365 days a year. That saves money, energy and water.
- Compact SizeKeltech tankless water heating solutions are modular and take up a fraction of the space compared to a boiler.
- Built to LastKeltech water heaters feature quality control systems and premium materials like copper and brass to meet the most demanding conditions.
Keltech’s commercial grade tankless water heaters and fluid heating solutions are built for commercial and industrial process heating applications. Keltech heaters are used in applications as varied as:
• Safety shower and emergency eyewash applications
• Large industrial process heating
• Sporadic water heating for laboratories
• Light industrial process heating
• Aircraft hot water delivery systems
• Residential systems
• De-ionized water heating solutions
• Corrosive fluid heating protection systems
• Non-flammable fluid heating applications
• Other on-demand water heating applications
• Bio-diesel vegetable oil heating at 230°F
• Removing residue and oils from machine parts
• Circuit board flux removal
• Legionella prevention
• ANSI compliant safety shower heaters and systems
• ANSI compliant emergency eyewash heaters
Tankless Water Heaters and Water Heating Solutions for Extreme Environments
Freeze ProtectionWater heating solutions can be freeze protected to perform when air temperatures get as cold as -30°F.
Explosion Proof
Keltech also manufactures Class 1 Div 2 explosion proof solutions for highly volatile or flammable areas where water or chemicals must be heated.
NEMA 4x Enclosures
Keltech also produces water heaters that can be sealed in NEMA 4x enclosures to protect the investment from corrosive conditions and hostile environments.
Specialty ApplicationsKeltech also engineers and manufactures custom built tankless water heating solutions that are capable of heating:
• De-ionized Water
• Reverse Osmosis Fluids
• Corrosive Fluids
• Non-Flammable Fluids
Saturday, June 27, 2009
Determining Your Water Flow Rate for Tankless Water Heaters
Selecting tankless hot water heaters isn't very difficult. Select one based on the maximum amount of hot water to meet your peak demand.
Selecting Tankless Water Heaters
Selecting tankless hot water heaters isn't very difficult. Select one based on the maximum amount of hot water to meet your peak demand. Use the following assumptions on flow for various appliances to find the size of unit that is right for your purposes: Faucets: 1.0 gallons (3.78 liters) to 2.5 gallons (9.46 liters) per minute.
Low-flow showerheads: 1.0 gallons (3.78 liters) to 2 gallons (7.57 liters) per minute. Older standard shower heads: 2.5 gallons (9.46 liters) to 3.0 gallons (11.36 liters) per minute.
Clothes washers and dishwashers: 1 gallon (3.79 liters) to 2 gallons (7.57 liters) per minute.
Unless you know otherwise, assume that the incoming temperature is 55° F (12.78° C). You will want your water heated to 110° F (43.33° C) for most uses. To determine how much of a temperature rise you need, subtract the incoming temperature from the desired output temperature. In this example, the needed rise is 55° F (12.78° C).
List the number of hot water devices you expect to have open at any one time, and add up their flow rates. This is the desired flow rate for the heater. Selecting a tankless water heater is nearly impossible without knowing the flow rate you need.
As an example, assume the following conditions: One hot faucet open with a flow rate of 1.0 gallons (3.79 liters) per minute. One person bathing using a shower head with a flow rate of 2.5 gallons (9.46 liters) per minute. Add the two flow rates together. If the inlet water temperature is 55° F (12.78° C), the needed flow rate through the heater would need to be no greater than 3.5 gallons (13.25 liters) per minute. Faster flow rates or cooler inlet temperatures will reduce the temperature at the most distant faucet.
Selecting Tankless Water Heaters
Selecting tankless hot water heaters isn't very difficult. Select one based on the maximum amount of hot water to meet your peak demand. Use the following assumptions on flow for various appliances to find the size of unit that is right for your purposes: Faucets: 1.0 gallons (3.78 liters) to 2.5 gallons (9.46 liters) per minute.
Low-flow showerheads: 1.0 gallons (3.78 liters) to 2 gallons (7.57 liters) per minute. Older standard shower heads: 2.5 gallons (9.46 liters) to 3.0 gallons (11.36 liters) per minute.
Clothes washers and dishwashers: 1 gallon (3.79 liters) to 2 gallons (7.57 liters) per minute.
Unless you know otherwise, assume that the incoming temperature is 55° F (12.78° C). You will want your water heated to 110° F (43.33° C) for most uses. To determine how much of a temperature rise you need, subtract the incoming temperature from the desired output temperature. In this example, the needed rise is 55° F (12.78° C).
List the number of hot water devices you expect to have open at any one time, and add up their flow rates. This is the desired flow rate for the heater. Selecting a tankless water heater is nearly impossible without knowing the flow rate you need.
As an example, assume the following conditions: One hot faucet open with a flow rate of 1.0 gallons (3.79 liters) per minute. One person bathing using a shower head with a flow rate of 2.5 gallons (9.46 liters) per minute. Add the two flow rates together. If the inlet water temperature is 55° F (12.78° C), the needed flow rate through the heater would need to be no greater than 3.5 gallons (13.25 liters) per minute. Faster flow rates or cooler inlet temperatures will reduce the temperature at the most distant faucet.
Friday, June 26, 2009
Replacements for Bosch Tankless Heat Exchangers
Today we sold and shipped a replacement heat exchanger for a Bosch 125VP tankless water heater.
This customer told me that he loved his Bosch water heater and has had it for -- get this -- 20 years!
He told me that he has maintained it regularly with a descaling solution and that he loves his water heater! We breifly discussed the merits of purchasing a new Bosch tankless water heater, but he told me that he is very happy with the heater he has.
Global Pro Tankless Supply can supply customers with replacement heat exchangers for many of the older model tankless water heaters. Just give us a call and we can get you a quote on any of the following legacy Bosch AquaStar heaters:
Bosch AquaStar 38B
Bosch AquaStar 125B
Bosch AquaStar 125BL
Bosch AquaStar 125BS
Bosch AquaStar 125HX
Bosch AquaStar 125X
Bosch AquaStar 250SX
Bosch AquaStar 250SXO
Bosch AquaStar 240FX
Bosch AquaStar 80VP
Bosch AquaStar 125VP
Bosch AquaStar 170VP
Steve
This customer told me that he loved his Bosch water heater and has had it for -- get this -- 20 years!
He told me that he has maintained it regularly with a descaling solution and that he loves his water heater! We breifly discussed the merits of purchasing a new Bosch tankless water heater, but he told me that he is very happy with the heater he has.
Global Pro Tankless Supply can supply customers with replacement heat exchangers for many of the older model tankless water heaters. Just give us a call and we can get you a quote on any of the following legacy Bosch AquaStar heaters:
Bosch AquaStar 38B
Bosch AquaStar 125B
Bosch AquaStar 125BL
Bosch AquaStar 125BS
Bosch AquaStar 125HX
Bosch AquaStar 125X
Bosch AquaStar 250SX
Bosch AquaStar 250SXO
Bosch AquaStar 240FX
Bosch AquaStar 80VP
Bosch AquaStar 125VP
Bosch AquaStar 170VP
Steve
Labels:
125B,
125BL,
125BS,
125HX,
125VP,
125X,
170VP,
240fx,
250SX,
250SXO,
38B,
80VP,
bosch,
heat exchanger,
replacement parts
Tuesday, June 23, 2009
Installing Un-Sealed Bosch Tankless Water Heaters in Enclosed Occupied Spaces
Installation of un-sealed gas utilization equipment in bedrooms, bathrooms or any occupied rooms with doors normally kept closed is prohibited by standards set forth in the National Fuel Gas Code. These standards conform to all known building codes throughout North America and are included in your product installation manual.
Oxygen deprivation and carbon monoxide poisoning are serious health risks that can result from such installations, due largely to the lack of combustion and ventilation air present in enclosed spaces. Premature appliance failure is also a consequence of lack of combustion and ventilation air. For details pertaining to combustion and ventilation air requirements for your Bosch water heater, please refer to the product installation manual or contact a qualified service agency. Failure to properly install Bosch water heaters voids all warranties, written or implied.
If your un-sealed Bosch tankless water heater is installed in a bathroom, bedroom or enclosed occupied space, you are strongly urged you to have the unit relocated and its installation inspected by a qualified gas service agency.
Oxygen deprivation and carbon monoxide poisoning are serious health risks that can result from such installations, due largely to the lack of combustion and ventilation air present in enclosed spaces. Premature appliance failure is also a consequence of lack of combustion and ventilation air. For details pertaining to combustion and ventilation air requirements for your Bosch water heater, please refer to the product installation manual or contact a qualified service agency. Failure to properly install Bosch water heaters voids all warranties, written or implied.
If your un-sealed Bosch tankless water heater is installed in a bathroom, bedroom or enclosed occupied space, you are strongly urged you to have the unit relocated and its installation inspected by a qualified gas service agency.
Subscribe to: